York and Coleman Furnace Flash Codes: What Each LED Pattern Means

Featured image for: York and Coleman Furnace Flash Codes: What Each LED Pattern Means

Table of Contents

York, Coleman, and Luxaire furnaces are built on the same manufacturing platform: historically under Johnson Controls, and under Bosch since Bosch acquired Johnson Controls’ residential HVAC business in a deal that closed July 31, 2025. The control boards, parts, and diagnostic logic are shared across all three nameplates. But flash-code meanings are tied to the control board installed in your specific furnace, not to the brand name on the door. A furnace built in 2010 and one built in 2022 can use completely different code maps even under the same brand. Count your blinks, then match them against your furnace’s own door sticker or manual before acting on any chart, including this one.

Are York, Coleman, and Luxaire really the same furnace?

Yes, at the manufacturing level. All three are nameplates built on shared platforms under the same corporate parent (Johnson Controls historically, Bosch now), and installation manuals published during the JCI era cover multiple brands under one document for a given model line. Parts (igniters, flame sensors, pressure switches, gas valves) are cross-catalogued and interchangeable across the three brands for a matching model.

What is not shared automatically: the flash-code table. Two furnaces from two different brands but the same control-board generation will match. Two furnaces from the same brand but different board generations often won’t. This guide documents the code chart for the TM9V*C-series two-stage variable-speed board (the control used in a large share of current 96% AFUE York, Coleman, and Luxaire condensing furnaces), verified against the manufacturer’s own installation manual.

How to read the LED

  1. Open the furnace’s lower door panel. The LED is on the integrated control board.
  2. Slow green flash (2 seconds on, 2 seconds off): normal operation, no thermostat call.
  3. Slow amber flash: normal operation, actively running a heat call.
  4. Counted red flashes: on 1/3 second, off 1/3 second, repeated the number of times equal to the code, then a 2-second pause before repeating. Count a full cycle twice to confirm.
  5. LED steady off: no power to the board, or a blown fuse on the board.
  6. Steady on, any color: control board failure. Cycle power; if the LED stays steady on, the board needs replacing.

Most common fault by far: Code 3 (pressure switch didn’t close), usually from a blocked condensate drain on a condensing furnace. Check that first.

York/Coleman/Luxaire TM9V-series flash codes: verified chart

FlashesFaultWhat it meansDIY or call?
Slow greenNormal, no callStandbyN/A
Slow amberNormal, heat callRunning normallyN/A
Steady offNo power / blown fuseCheck breaker, door switch, board fuseDIY check
Steady on (any color)Control failureCycle power; replace board if it recursCall a pro
Continuous amberFlame sense current below 1.5 microampsDirty flame sensor or low gas flowDIY start
1 redFlame sensed with no call for heatLeaking or slow-closing gas valveCall a pro
2 redPressure switch stuck closedFaulty switch, water in the hose, or miswiringDIY check
3 redPressure switch failed to closeBlocked condensate drain, blocked vent, faulty inducerDIY check
4 redMain limit switch openDirty filter, restricted airflow, blower issueDIY first
5 redLimit circuit open 15+ minutesManual-reset rollout switch trip (hard lockout)Call a pro
6 redPressure switch opened 4x during a call for heatIntermittent inducer or pressure-switch faultCall a pro
7 redFlame not established after 3 ignition trialsGas valve, igniter, flame sensor, or low gas pressureDIY start, call if unresolved
8 redFlame lost 5 times (4 recycles) during the heat cycleLow gas pressure, dirty/faulty flame sensor, faulty gas valveDIY start, call if unresolved
9 redReversed line-voltage polarity or grounding faultFurnace wiring, disconnect, or panel connectionCall an electrician
10 redGas valve energized with no call for heatGas valve or gas valve wiring faultCall a pro
11 redLimit circuit open 5–15 minutesLikely failed blower motor or blower wheelCall a pro
12 redLoose or missing model ID plugReseat or replace the ID plugDIY check
13 redHigh-fire pressure switch open when it should be closedPartially blocked vent, loose wire, or faulty switchDIY check, call if unresolved
4 amberThermostat sending Y (cool) without G (fan)Wiring problem at the thermostat, not a failureDIY check

Confirm against the sticker on your own door panel. This chart documents the TM9V*C two-stage variable-speed board. If your furnace uses a different control board, including an older York, Coleman, or Luxaire from a prior generation, the numbers can mean something different. Match the model number on your rating plate to your furnace’s own manual before acting on any code.

Code-by-code: what to check first

2 red flashes: Pressure switch stuck closed

The board found the pressure switch closed before the inducer started, when it should read open. Check for water pooled in the rubber hose between the switch and the inducer housing, and drain it. Test the switch with a multimeter: it should show no continuity at rest.

3 red flashes: Pressure switch failed to close

The inducer started but draft pressure never registered. On a condensing furnace (90%+ AFUE), a blocked condensate drain trap is the leading cause. Clear it with a wet-dry vac at the drain outlet or by flushing with water. On an 80% AFUE unit with no condensate drain, check the metal flue pipe for a blockage (bird nests, rust, ice in extreme cold).

4 red flashes: Main limit switch open

The furnace overheated and the limit switch tripped to protect the heat exchanger. Check the filter first, every time. A clogged filter is the leading cause. Replace it, cycle power off for 30 seconds, and restore. If Code 4 returns with a clean filter, check for closed supply registers, a blocked return grille, or a blower wheel caked in dust.

5 red flashes: Manual-reset rollout switch (hard lockout)

The limit circuit stayed open for more than 15 minutes, which the control reads as a rollout switch trip: flames burning outside the burner box. Causes include a blocked flue, abnormally high gas pressure, or a cracked heat exchanger.

Safety box: stop using the furnace and close the manual gas shutoff valve. This is a hard lockout. Power must be cycled to reset it, and the control will not auto-restart. A cracked heat exchanger from a rollout event can put carbon monoxide into the living space. Call a licensed HVAC technician before restarting; do not reset and walk away.

7 red flashes: Flame not established after 3 ignition trials

The furnace tried to light three times and failed. Check that the manual gas shutoff is fully open, then work through gas pressure, a cracked or dirty hot-surface igniter, and a dirty flame sensor (clean the metal rod with 0000 steel wool). See Furnace Hot-Surface Igniter: Symptoms and Replacement and Furnace Flame Sensor: Symptoms and Cleaning. The furnace locks out for one hour and retries on its own.

9 red flashes: Reversed polarity or grounding fault

The 115V supply has reversed hot/neutral, or the ground connection is missing. The furnace will not start ignition until this is fixed. Call an electrician or HVAC tech to check the furnace wiring, disconnect, and panel connection. Don’t attempt line-voltage wiring yourself unless you’re qualified.

When to call a licensed HVAC technician

  • Code 5 (rollout, hard lockout) or 9 (polarity/grounding): don’t reset and rerun. Get it inspected first.
  • Code 6, 8, or 10 if the fault keeps returning after your own checks.
  • Any gas-valve or ignition fault (1, 7, 10) that isn’t resolved by a first pass at the filter, igniter, and flame sensor.
  • Steady-on LED after a power cycle: the control board itself has failed.

FAQ

Are York, Coleman, and Luxaire furnaces really the same? The brands share a manufacturing platform, control boards, and parts, historically under Johnson Controls and now under Bosch. But the flash-code meanings depend on which control board generation is in your specific furnace, not the brand name. Always confirm against your unit’s own door sticker or manual.

How do I reset my York or Coleman furnace after a lockout? Turn the power switch off for 30 seconds, then restore. This clears a soft lockout. A hard lockout (Code 5, 9, 11) also requires the power cycle, but don’t do it repeatedly without fixing the underlying cause. Cycling power on a live gas-valve or rollout fault is how a real problem gets ignored.

Code 3 shows up every cold morning. What’s happening? On a condensing furnace, the condensate drain trap is a common freeze point if it runs through an unheated basement or garage wall. Insulate the trap, or add a small amount of RV antifreeze to the trap to prevent overnight freezing.

My furnace shows Code 4 and the blower sounds slow. Is that related? Yes. A slow blower reduces airflow across the heat exchanger, which is exactly what trips the limit switch. Check the blower capacitor first (a $10–25 part and the most common cause of a weak blower) before assuming the motor itself has failed.

Related guides

Last reviewed August 2026. Flash-code meanings are specific to your control board generation. Verify against your furnace’s own door sticker or manual before acting.

About the Author – Dan Golden
Picture of Dan Golden

Dan Golden

Dan Golden is a Chicago-based developer, entrepreneur, and proptech builder focused on making homes smarter and more sustainable. He is the creator of HomeDoc, a home management platform that helps homeowners track maintenance, warranties, and projects, and HomeEnergyPlanner, a resource for evaluating energy upgrades and efficiency improvements. On the commercial and enterprise side, Dan co-founded Pandotic, a product studio behind BidSmart, an AI-powered HVAC bid analysis tool, and LEEDsmart, a platform for navigating green building certification. His work in sustainable real estate also extends to ESGsource, where he covers green building trends and ESG developments in the built environment.