The PRO 2000 Vertical is a basic programmable thermostat for heat pump systems specifically. It doesn’t support gas or oil furnaces at all, so confirm your system type before buying one if you’re shopping rather than replacing a like-for-like unit.
What it supports
- System type: heat pump only. Not compatible with conventional gas or oil furnace systems.
- Stages: 2 heat / 1 cool.
- Programming: 5-2 day (one schedule for weekdays, a second schedule for the weekend), with a manual changeover between heat and cool rather than automatic.
- Power: dual powered, meaning it runs on 24V AC from your system’s transformer with battery backup, rather than battery-only.
Specs
| Spec | Value |
|---|---|
| Power | 20-30 VAC, 0.02-1 A, 50/60 Hz |
| Stages | 2 heat / 1 cool (heat pump) |
| Programming | 5-2 day |
| Changeover | Manual |
| Heating range | 40-90°F |
| Cooling range | 50-99°F |
| Humidity range | 5-90% RH, non-condensing |
| Dimensions | 4-11/16″ H x 2-7/8″ W x 1-1/8″ D |
Installation basics
This is a standard low-voltage thermostat install: shut off power to your HVAC system at the breaker, remove the old thermostat, and match wire-to-terminal (not wire-color-to-terminal) on the new base plate. Since this model is heat-pump-specific, expect to see the O/B reversing valve terminal in your wiring, which a straight gas-furnace thermostat wouldn’t have. If you’re not sure how to read your existing wiring, see our general thermostat wiring guide before starting.
Safety box: shut off power at the breaker before disconnecting any wiring, and if your system uses anything beyond standard low-voltage control wiring, that’s a licensed HVAC tech’s job.
Built-in compressor protection
Like most Honeywell programmable thermostats, the PRO 2000 Vertical holds off restarting the compressor for a few minutes after it stops, to protect it from restarting against residual refrigerant pressure. If the display is flashing after a mode change or a power interruption, that’s this protection delay working as intended, not a fault. See our Honeywell snowflake blinking guide for how long that’s normal and when it isn’t.
Where to find the official manual
Honeywell’s own installation and user manuals for this exact model are available through honeywellhome.com, searchable by the model number TH2210DV1006/U.
FAQ
Can I use the PRO 2000 Vertical with a gas furnace? No. This model is built for heat pump systems only. A conventional gas or oil furnace needs a different Honeywell model.
Does it need a C-wire? It’s dual powered, meaning it runs on your system’s 24V AC with battery backup rather than battery-only. Check your existing wiring for a C terminal; most heat pump systems already have one run for the outdoor unit’s controls.
What does 5-2 day programming mean? One schedule applies to all five weekdays, and a second schedule applies to both weekend days, rather than a fully custom schedule for every individual day of the week.
Why is my display flashing after I installed it? That’s the built-in compressor protection delay, not a wiring problem. Wait a few minutes; see our snowflake blinking guide for the full explanation.
This guide is part of our full Honeywell Home Thermostat hub: wiring, setup, and troubleshooting for every current series.
![Honeywell Thermostat Blowing Cold Air on Heat Setting [Fixed] 1 Honeywell furnace thermostat](https://thermostating.com/wp-content/uploads/2022/09/honeywell-furnace-thermostat.png)
![New Honeywell Thermostat Blowing Hot Air On Cool [Solved] 3 Thermostat fix](https://thermostating.com/wp-content/uploads/2022/11/thermostat-fix.png)